Title : Evaluation of two cad software on the adaptation of digitally constructed maxillary complete denture

Abstract:

Aims: This study was conducted to evaluate the adaptation of maxillary complete denture designed by two different open computer-aided design software programs (3Shape and Exocad) using Geomagic surface matching software.
Settings and Design: This was a nonrandomized crossover clinical trial.
Materials and Methods: Twenty completely edentulous patients were selected in this study. Forty complete dentures were designed using two different software programs: twenty dentures were designed by 3Shape software, and the other twenty dentures were designed by Exocad software. Maxillary dentures were evaluated regarding their adaptation by measuring the deviations that occurred between the fitting surface of the three-dimensional printed dentures, and the scanned master casts using Geomagic surface matching software. Statistical Analysis Used: An unpaired t-test was used for statistical analysis.
Results: According to the positive average deviation value that represented pressure areas, 3Shape-designed maxillary dentures showed significantly lower mean deviation values (0.041115 ± 0.018165 mm) than Exocad?designed maxillary dentures (0.500665 ± 0.032619 mm). Regarding the negative average deviation values that represented the gap areas, Exocad-designed maxillary dentures showed significantly lower mean deviation values (0.161555 ± 0.007842 mm) than 3Shape?designed maxillary dentures (0.231350 ± 0.009146 mm). The results of the total average deviation values showed significantly lower mean deviation values (0.096950 ± 0.008868 mm) of 3Shape?designed maxillary dentures than Exocad-designed maxillary dentures (0.250755 ± 0.021154 mm).
Conclusion: 3Shape and Exocad software programs produced acceptable maxillary dentures regarding denture adaptation. However, maxillary dentures designed by 3 Shape software showed better adaptation than maxillary dentures designed by Exocad software. Keywords: 3Shape software, computer?aided design, denture adaptation, digital complete dentures, Exocad software, Geomagic software

Audience Takes Away Notes:

  • Is this research that other faculty could use to expand their research or teaching? yes
  • Does this provide a practical solution to a problem that could simplify or make a designer’s job more efficient? yes
  • Will it improve the accuracy of a design, or provide new information to assist in a design problem? yes

Biography:

Professor of Prosthodontics at Faculty of Dentistry, British University in Egypt, 2017-present. A. Professor of Prosthodontics at Faculty of Dentistry, British University in Egypt, 2012-2017. Program Director and Head of Prosthodontics Department at Faculty of Dentistry, British University in Egypt, 2012-present. Program Director and Clinic Instructor in Membership of Restorative Dentistry (MRD) recognized by the Royal College of Surgeons of Edinburgh. Program Director and Clinic Instructor in Diploma of Implants for Postgraduates. Ph.D. Prosthodontics, Faculty of Dentistry, Ain Shams University 2007. M.Sc. Prosthodontics, Crown and Bridge and Dental Materials, Faculty of Dentistry, Cairo University, 2000. B.D.S, Oral and Dental Medicine, Faculty of Dentistry, Caro University 1994.